SuperNuclear High-Temperature Tray Cable

1X Technologies SuperNuclear High-Temperature Tray Cable

SuperNuclear – UL Type TC/TC-ER and cUL CIC TC-ER

600V Power & Control Tray Cable – Class 1 Div 2 Hazardous Areas

Conductor/90°C Wet or Dry, Non-UL 105C+, 90C/130C/250C

For Cable Tray Use – Sunlight Resistant – For Direct Burial

 

SuperNuclear Cable Insulation:

Nuclear Grade Heat, moisture, flame, and chemical resistant, mechanically rugged ethylene-propylene insulating compound. The properties of the ferromagnetic resonance substantially enhances the well-known features of ethylene-propylene rubber insulations.

 

SuperNuclear Cable Overall Jacket:

Hard Usage, Rugged PVC jacket is mechanically rugged and has excellent resistance to most chemicals, is sunlight resistant, and passes (UL) Vertical Flame Tests.

 

SuperNuclear Cable Applications:

SuperNuclear TC-ER tray cable is permitted for use on power, lighting, control, and signal circuits; indoors or outdoors; in cable trays, raceways, direct burial in the ground, or where supported in outdoor locations by a messenger wire; for Class 1 circuits as permitted in Article 725 of the NEC; and in cable trays in Class I, Division 2 hazardous locations in industrial establishments where the conditions of maintenance and supervision ensure that only qualified persons will service the installation. Cables marked TC-ER may also be used between a cable tray and the utilization equipment or device when installed in accordance with the NEC.

 

SuperNuclear Cable Specifications

SuperNuclear Conductors:

Uncoated soft copper per ASTM B-3. Sizes smaller than #8 are compress stranded per ASTM B-8. Sizes #8 and larger are compact stranded per ASTM B-496.

 

SuperNuclear Insulation:

Nuclear Grade meets or exceeds requirements of UL 1581, ICEA S-73-532 (NEMA WC57) and ICEA S-95-658 NEMA WC70 Type II insulation.

 

SuperNuclear Color Coding:

Contact us for Colors Data Sheet. For sizes #8 AWG and larger black conductors with surface printing of numbers per ICEA S-73-532 NEMA/WC57 Method 4.

 

SuperNuclear Grounding Conductor:

Where indicated, bare stranded copper per ASTM B-8, or compact round per ASTM B-496, Class B & NEC Table 250.122.

 

SuperNuclear Assembly:

Conductors cabled in accordance with UL 1277 and 1309 using fillers, as necessary, with a cable tape overall.

 

SuperNuclear Overall Jacket:

Complies with UL 1277 and 1309. The Nuclear Grade compound meets or exceeds the requirements of UL 1581. UL Listed as Type TC or TC-ER cable with a sunlight resistant low-temperature jacket and for direct burial. Sizes 4 AWG and larger without a grounding conductor are Type TC only (not ER).

 

SuperNuclear Cable Features:

Insulated conductors are UL rated VW-1. 90°C continuous rating in wet or dry 130°C emergency overload rating 250°C short circuit rating. SuperNuclear Type TC-ER are quality control inspected to meet or exceed applicable industry standards. Resistant to moisture and most chemical atmospheres. Thermal stability at elevated temperatures, and High-Temperatures. Flexible, easy to install and terminate. High dielectric strength. Installation Temperature -40°C.

 

SuperNuclear Applicable Industry Standards:

UL listed for cable tray use, direct burial, in ducts, and sunlight resistant. • Vertical Tray Flame Tests; IEEE 383-1974, FT4/IEEE 1202, UL 1277, Sizes 250 kcmil and larger meet ICEA T-29-520 (210,000 BTU/hr). • OSHA Acceptable • UL certified to IEEE 1580 – Marine Shipboard Cable rated 600/1000V. • ABS Type approved; API-RP-14F, IEEE 45 & 1202, 46 CFR 111.60. • CSA C22.2 No. 239 Type CIC for sizes 4/0 AWG and smaller. • CSA C22.2 No. 230 Type TC-ER for sizes 4/0 AWG and smaller. • 1000V CSA Type CIC available for sizes 4/0 AWG and smaller.

 

SuperNuclear High-Temperature Tray Cable

Conductor Size AWG (strands)

Number of Conductors

Insulation Thickness-mils

Jacket Thickness-mils

Approx. O.D.-Inches

Approx. Net Wt (lbs/M’)

14(7x)

3

30

45

0.40

104

14(7x)

4

30

45

0.44

126

14(7x)

5

30

45

0.48

151

14(7x)

7

30

45

0.52

195

14(7x)

12

30

60

0.71

332

14(7x)

19

30

60

0.82

480

14(7x)

37

30

80

1.14

925

12(7x)

3

30

45

0.44

134

12(7x)

4

30

45

0.48

167

12(7x)

5

30

45

0.52

202

12(7x)

7

30

60

0.60

281

12(7x)

9

30

60

0.70

363

12(7x)

12

30

60

0.78

446

12(7x)

19

30

80

0.95

697

10(7x)

3

30

45

0.49

183

10(7x)

4

30

60

0.57

243

 

POWER CABLES

Conductor Size AWG/kcmil (strands)

Number of Phase Conductors

Insulation Thickness-mils

Jacket Thickness-mils

Approx. O.D.-Inches

Approx. Net Wt (lbs/M’)

12(7x)

3

12 (2)

30

0.48

162

10(7x)

3

10 (2)

30

0.62

223

8(7x)

3

10 (2)

45

0.72

332

6(7x)

3

8 (2)

45

0.80

482

4(7x)

3

8 (2)

45

0.82

703

2(7x)

3

6 (3)

45

0.99

997

1/0(7x)

3

6 (3)

55

1.18

1469

2/0(7x)

3

6 (3)

55

1.26

1819

4/0(7x)

3

4 (3)

55

1.48

2646

350(7x)

3

3 (3)

65

1.88

4301

500(7x)

3

2 (3)

65

2.14

5909