2000 MCM Cable Price – 2000 KCMIL Pricing. Data Spec.
It’s important to note that you’re able to get your 2000 MCM price, 2000 KCMIL Pricing to buy your copper and aluminum conductor cable today.
You won’t have to wait. We will help you right away.
Furthermore, while 2000 MCM is typically a non-stock size, we may have the specific 2000 MCM, 2000 KCMIL Cable type you need on the floor.
Please let us know what you are looking for.
We typically stock and sell 2000 MCM and 2000 KCMIL cable in 600 Volt, 1KV, 2KV, 5KV, 8KV, 15KV, 25KV, 35KV, 69KV, 138KV, 238KV, 345kV, 400kV, 500kV, up to 550KV.
Do you need help planning for an upcoming project, or need to buy something now?
Let us know, we would be happy to help you!
Call 1-888-651-9990 for assistance or email us below.
My Quick 2000 MCM / 2000 KCMIL Price ✅
Include your quantity required, wire & cable description, and delivery location in your message, and your 1X Technologies representative will respond with your 2000 MCM / 2000 KCMIL Wire & Cable pricing, quickly.
If you still have questions, call us at 1-888-651-9990. We are available to answer questions Monday through Friday, 9 am – 6 pm MST.
Wire & Cable applications for 2000 MCM / 2000 KCMIL.
2000 MCM Cable is a very rare size. So rare, that it is usually only utilized for a few distinct applications.
- First, 2000 MCM or 2000 KCMIL Subsea or Submarine Cable Applications.
- Second, 2000 MCM or 2000 KCMIL High Voltage Utility Power Cable / Traction Power Cable.
- Third, 2000 MCM or 2000 KCMIL Custom Cable Applications.
- Fourth, 2000 MCM or 2000 KCMIL Building Wire.
2000 MCM / 2000 KCMIL Subsea & Submarine Cable.
From Asia-Pacific to the Americas, and from Europe to the Middle East to Africa, 1X Technologies positions our capabilities at the heart of the development of power grids worldwide. Furthermore, helping major utilities in transmitting and distributing power to their customers through quality cables and wires. Additionally, unmatched in our manufacturing capabilities and with an unwavering commitment to R&D, we design, produce and install your submarine cables and systems, along with network components and value-added engineering services. Always aware of the need to minimize our impact on the planet, we’re constantly driving innovation in our industry. Specifically, we are always aiming to optimize our supply chain processes. Finally, we do everything we can to reduce your total cost of ownership and help you achieve sustainable, profitable growth when purchasing your 2000 MCM / 2000 KCMIL Submarine Cable.
From the National Oceanic and Atmospheric Administration on Submarine Cable:
It is a common misconception that most global communication is accomplished via satellite. In fact, over 95 percent of international data and voice transfers are currently routed through the many fiber optic cables that crisscross the world’s seafloors. See U.N. Env’t Programme World Conserv’n Monitoring Ctr., Submarine Cables and the Oceans: Connecting the World, at 3, UNEP-WCMC Biodiversity Series No. 31 (2009) [hereinafter “UNEP Report”]. The earliest submarine cables carried telegraphic traffic. The first successful trans-Atlantic submarine cable – a simple copper wire – became operational in 1866, delivering about 12 telegraphed words per minute. As technology and laying techniques improved, the submarine network expanded greatly. In September 1956, the era of submarine coaxial telephone communication began when two coaxial cables capable of carrying multiple voice channels came into service linking London and North America. Finally, in 1988, the first transoceanic fiber-optic cable was installed linking the U.S., the U.K, and France. Thereafter, the number of submarine fiber-option cables proliferated as they rapidly outperformed satellites in terms of the volume, speed, and economics of data and voice communication. Submarine cables are also an important means of power transmission—particularly in light of the ongoing development of offshore alternative energy generation facilities, such as wind farms.
Submarine cables clearly play a critical role in global communications.
For the United States, they provide connectivity between the contiguous United States and Alaska, Hawaii, American Samoa, Guam, the Northern Marianas, Puerto Rico, and the U.S. Virgin Islands – as well as connectivity with the rest of the world. They also support critical commercial, economic and national security endeavors. and they carry a majority of civilian, military and government offshore communications traffic. The success of submarine cables owes much to treaties which have been negotiated since 1884. Submarine cables are also subject to domestic regulations by most nations, including the United States which has a broad suite of domestic regulations applicable to cable-laying, maintenance, repair and removal operations.
2000 MCM / 2000 KCMIL High Voltage Utility Power Cable / 2000 KCMIL Traction Power Cable
1X Technologies provides high-voltage underground transmission solutions from end to end. We offer you the complete array of High-Voltage cable products, installation services, tools and equipment to meet your specific needs. And we’re with you every step of the way with responsive service, unmatched engineering support. and onsite project management—a commitment that has resulted in zero cable failures with over seven million feet of HV cable installed. When it comes to 2000 MCM Traction Power Cable we manufacture the best quality cable with the lowest order quantity and the fastest lead time. When you need a high-voltage underground transmission, 1X Technologies is your best option.
1X Technologies LLC 2000 MCM / 2000 KCMIL HV Cable Features:
- XLPE HV Power Cables 69kV through 500kV with Copper and Aluminum conductors 2000 MCM / 2000 KCMIL. Copper or Aluminum is a matter of customer preference and required current carrying capacity.
- Shield wires, welded and corrugated sheaths, and composite laminate sheaths available in copper or aluminum cover all applications.
- XLPE cables through 500 kV.
- We offer nearly unlimited options such as integrated or external optical fiber for distributed temperature sensing, fire retardant cable jackets, and cables with the highest fault current ratings.
- Special executions include long lengths and pipe retrofit cables.
- Cables made to AEIC, ICEA, and IEC specifications.
Custom 2000 MCM / 2000 KCMIL CUSTOM Applications
Simply put, whatever your specific need for a 2000 MCM Cable, we are ready to manufacture an excellent solution that will make you and your customer happy. Whether this custom cable is for Mining and Exploration or if it needed to complete a scientific venture, we are ready to show you just how excellent your choice was in choosing 1X Technologies to manufacture your 2000 MCM Cable.
Short Run Capability
Do you just need a short run of cable for your project? We specialize in manufacturing prototypes and short runs to help our customers when they need to finish a project or if they need to replace a damaged cable.
Rapid Manufacturing
Are you in an emergency situation where you need your cable delivered right away? Rapid manufacturing is our specialty. Call 1-888-651-9990 now.
2000 MCM / 2000 KCMIL Building Wire Applications
Perhaps the most common use for our 2000 MCM Wire is for building wire applications. 2000 MCM Is often used as a large Copper or Aluminum Feeder cable in commercial and industrial electrical construction.
The most Common Types of 2000 MCM, 2000 KCMIL building wire.
1- 2000 MCM Copper, 2000 KCMIL Copper THHN / THWN-2
2- 2000 MCM Copper, 2000 KCMIL Copper XHHW -2
3- 2000 MCM Copper, 2000 KCMIL Copper XLP— USE RHH-RHW -2
4- 2000 MCM Copper, 2000 KCMIL Copper MV-105 MV-90
5- 2000 MCM Copper, 2000 KCMIL Copper URD
6- 2000 MCM Aluminum, 2000 KCMIL Aluminum MV-105 MV-90
7- 2000 MCM Aluminum, 2000 KCMIL Aluminum URD
8- 2000 MCM Aluminum THHN, 2000 KCMIL Aluminum THHN
9- 2000 MCM Aluminum XHHW, 2000 KCMIL Aluminum XHHW
10- 2000 MCM Aluminum XLP— USE, 2000 KCMIL Aluminum XLP— USE
2000 MCM conversion to 2000 KCMIL (MCM to KCMIL)
First, KCMIL is an abbreviation for a Circular Mil. A circular mil is a unit of area, equal to the area of a circle with a diameter of one mil (one thousandth of an inch). It’s important to note that MCM is a measurement abbreviation for one thousand circular mils. This is a historical measurement of electrical & electronic wire & cable gauge sizes that has been passed down through generations. Accordingly,
1 MCM = 1 kcmil = 0.5067 square milimeters. A mil is 1/1000 inch
Thus, 2000 MCM is equal to 2000 KCMIL. They are interchangeable when describing the gauge size, or AWG size of your electrical and electronic wire & cable. We manufacture cable using both 2000 KCMIL and 2000 MCM to describe the wire & cable sizes.
2000 MCM / 2000 KCMIL Wire and Cable Voltage
- 500 Volt / .5KV 2000 MCM Wire, 2000 KCMIL Cable.
- 600 Volt / .6KV 2000 MCM Wire, 2000 KCMIL Cable.
- 1,000 Volt/ 1KV 2000 MCM Wire, 2000 KCMIL Cable.
- 2,000 Volt / 2KV 2000 MCM Wire, 2000 KCMIL Cable.
- 2,400 Volt/ 2.4KV 2000 MCM Wire, 2000 KCMIL Cable.
- 5,000 Volt / 5KV 2000 MCM Wire, 2000 KCMIL Cable.
- 8,000 Volt / 8KV 2000 MCM Wire, 2000 KCMIL Cable.
- 15,000 Volt / 15KV 2000 MCM Wire, 2000 KCMIL Cable.
- 25,000 Volt / 25KV 2000 MCM Wire, 2000 KCMIL Cable.
- 35,000 Volt / 25KV 2000 MCM Wire, 2000 KCMIL Cable.
- 69,000 Volt / 69KV 2000 MCM Wire, 2000 KCMIL Cable.
- 138,000 Volt / 138KV 2000 MCM Wire, 2000 KCMIL Cable.
- 230,000 Volt / 230KV 2000 MCM Wire, 2000 KCMIL Cable.
- 400,000 Volt / 400KV 2000 MCM Wire, 2000 KCMIL Cable.
- 500,000 Volt / 500KV 2000 MCM Wire, 2000 KCMIL Cable.
Popular 2000 MCM, 2000 KCMIL 600 Volt Cable Styles:
2000 MCM, 2000 KCMIL 600 Volt – 600V Copper THHN/THWN-2
2000 MCM / 2000 KCMIL 600-volt Copper THHN THWN-2 is used as a building wire for commercial and industrial applications. THHN stands for Thermoplastic High Heat-resistant Nylon-coated. Additionally, our 2000 MCM THHN is also THWN-2 Rated and can be manufactured with these jacket colors:
- 1) 2000 MCM THHN/THWN-2 Black Jacket
- 2) 2000 MCM THHN/THWN-2 Red Jacket
- 3) 2000 MCM THHN/THWN-2 Blue Jacket
- 4) 2000 MCM THHN/THWN-2 White Jacket
- 5) 2000 MCM THHN/THWN-2 Brown Jacket
- 6) 2000 MCM THHN/THWN-2 Orange Jacket
- 7) 2000 MCM THHN/THWN-2 Yellow Jacket
- 8) 2000 MCM THHN/THWN-2 Gray Jacket
- 9) 2000 MCM THHN/THWN-2 Pink Jacket
- 10) 2000 MCM THHN/THWN-2 Purple (Violet) Jacket
- 11) 2000 MCM THHN/THWN-2 Green Jacket
- *All these THHN colors are available with factory-applied Phase I.D. Stripes / Striping.
2000 MCM, 2000 KCMIL Copper 600 Volt, 600V XHHW -2 (Available as VW-1)
2000 MCM / 2000 KCMIL 600-volt Copper XHHW -2 is used as a building wire for commercial and industrial applications when a more durable crosslink cable in needed instead of cheaper, less durable PVC. XHHW stands for XLPE (cross-linked polyethylene) High Heat-resistant Water-resistant. Additionally, our 2000 MCM XHHW -2 is also available with a VW-1 rating and can be manufactured with these jacket colors:
- 1) 2000 MCM XHHW -2 Black Jacket
- 2) 2000 MCM XHHW -2 Red Jacket
- 3) 2000 MCM XHHW -2 Blue Jacket
- 4) 2000 MCM XHHW -2 White Jacket
- 5) 2000 MCM XHHW -2 Brown Jacket
- 6) 2000 MCM XHHW -2 Orange Jacket
- 7) 2000 MCM XHHW -2 Yellow Jacket
- 8) 2000 MCM XHHW -2 Gray Jacket
- 9) 2000 MCM XHHW -2 Pink Jacket
- 10) 2000 MCM XHHW -2 Purple (Violet) Jacket
- 11) 2000 MCM XHHW -2 Green Jacket
- All these XHHW colors are available with factory-applied Phase I.D. Stripes / Striping.
2000 MCM, 2000 KCMIL Copper XLP— USE -2 RHH-RHW -2 600 Volt, 600V
First, 2000 MCM / 2000 KCMIL 600-volt Copper XLP— USE RHH-RHW -2 is used as a building wire for commercial and industrial applications when a more durable crosslink cable in needed instead of cheaper, less durable PVC, and has thicker insulation than regular XHHW. XLP— USE stands for Cross-Linked Polyethylene – Underground Service Entrance. 2000 MCM XLP— USE RHH-RHW -2 can be manufactured with these jacket colors:
- 1) 2000 MCM XLP— USE RHH-RHW -2 Black Jacket
- 2) 2000 MCM XLP— USE RHH-RHW -2 Red Jacket
- 3) 2000 MCM XLP— USE RHH-RHW -2 Blue Jacket
- 4) 2000 MCM XLP— USE RHH-RHW -2 White Jacket
- 5) 2000 MCM XLP— USE RHH-RHW -2 Brown Jacket
- 6) 2000 MCM XLP— USE RHH-RHW -2 Orange Jacket
- 7) 2000 MCM XLP— USE RHH-RHW -2 Yellow Jacket
- 8) 2000 MCM XLP— USE RHH-RHW -2 Gray Jacket
- 9) 2000 MCM XLP— USE RHH-RHW -2 Pink Jacket
- 10) 2000 MCM XLP— USE RHH-RHW -2 Purple (Violet) Jacket
- 11) 2000 MCM XLP— USE RHH-RHW -2 Green Jacket
- All these XLP— USE colors are available with factory-applied Phase I.D. Stripes / Striping.
Popular 2000 MCM, 2000 KCMIL Medium Voltage 1KV, 2KV, 5KV, 8KV, 15KV, 25K, 35KV Cable Styles
1KV / 2KV
2000 MCM, 2000 KCMIL 1KV/2KV Aluminum (PV) Photovoltaic Aluminum Solar Feeder Cable
2000 MCM, 2000 KCMIL 1KV/2KV Aluminum PV Cable is popular for use in solar and wind power generation. We typically manufacture this with a black jacket, and if it’s not in stock we can usually have your order ready within 1 to 2 weeks. You may also order this cable with custom armor.
5KV / 8KV
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or Aluminum XLP MV-90, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 5KV Copper or aluminum XLP MV-90 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or Aluminum XLP MV-90, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or aluminum XLP MV-90 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or Aluminum EPR MV-105, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or aluminum EPR MV-105 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or Aluminum EPR MV-105, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 5KV / 8KV Copper or aluminum EPR MV-105 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
15KV
2000 MCM, 2000 KCMIL 15KV Copper or Aluminum XLP MV-90, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 15 KV Copper or aluminum XLP MV-90 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 15KV Copper or Aluminum XLP MV-90, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 15 KV Copper or aluminum XLP MV-90 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 15KV Copper or Aluminum EPR MV-105, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 15KV Copper or aluminum EPR MV-105 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
2000 MCM, 2000 KCMIL 15KV Copper or Aluminum EPR MV-105, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 15KV Copper or aluminum EPR MV-105 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
25KV
2000 MCM, 2000 KCMIL 25KV Copper or Aluminum XLP MV-90, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 25 KV Copper or aluminum XLP MV-90 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 25KV Copper or Aluminum XLP MV-90, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 25 KV Copper or aluminum XLP MV-90 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 25KV Copper or Aluminum EPR MV-105, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 25KV Copper or aluminum EPR MV-105 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
2000 MCM, 2000 KCMIL 25KV Copper or Aluminum EPR MV-105, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 25KV Copper or aluminum EPR MV-105 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
35KV
2000 MCM, 2000 KCMIL 35KV Copper or Aluminum XLP MV-90, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 35 KV Copper or aluminum XLP MV-90 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 35KV Copper or Aluminum XLP MV-90, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 35 KV Copper or aluminum XLP MV-90 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 90C with TR-XLP insulation.
2000 MCM, 2000 KCMIL 35KV Copper or Aluminum EPR MV-105, Copper Tape Shield Power Cable
2000 MCM, 2000 KCMIL 35KV Copper or aluminum EPR MV-105 with a Copper Tape Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
2000 MCM, 2000 KCMIL 35KV Copper or Aluminum EPR MV-105, Copper Wire Shield Power Cable
2000 MCM, 2000 KCMIL 35KV Copper or aluminum EPR MV-105 with a Copper Wire Shield is used in primary power and distribution circuits. Additionally, it’s in industrial and commercial installations, power circuits in generating plants where a line to ground fault current are within shield capabilities. Rated 105C with EPR Rubber insulation.
2000 MCM Cable Price / 2000 KCMIL Cable Pricing.
Do you need a quick price on 2000 KCMIL Cable or 2000 MCM Wire? We can help with everything from clearance 2000 MCM pricing on overstock material to custom 2000 KCMIL pricing. Your pricing will depend on a variety of factors including:
- Total Footage required.
- If Copper or Aluminum is required. Copper will be more expensive.
- Shielding and types of shielding used.
- Insulation Type required.
- Shipping location.
Contact us now for a current price on 2000 MCM / 2000 KCMIL cable: 1-888-651-9990
2000 MCM / 2000 KCMIL Voltage Drop Calculations
DC / single phase calculation
The voltage drop V in volts (V) is equal to the wire current I in amps (A) times 2 times one-way wire length L in feet (ft) times the wire resistance per 1000 feet R in ohms (Ω/kft) divided by 1000:
Vdrop (V) = Iwire (A) × Rwire(Ω)
= Iwire (A) × (2 × L(ft) × Rwire(Ω/kft) / 1000(ft/kft))
The voltage drop V in volts (V) is equal to the wire current I in amps (A) times 2 times one way wire length L in meters (m) times the wire resistance per 1000 meters R in ohms (Ω/km) divided by 1000:
Vdrop (V) = Iwire (A) × Rwire(Ω)
= Iwire (A) × (2 × L(m) × Rwire (Ω/km) / 1000(m/km))
3 phase calculation
The line to line voltage drop V in volts (V) is equal to square root of 3 times the wire current I in amps (A) times one way wire length L in feet (ft) times the wire resistance per 1000 feet R in ohms (Ω/kft) divided by 1000:
Vdrop (V) = √3 × Iwire (A) × Rwire (Ω)
= 1.732 × Iwire (A) × (L(ft) × Rwire (Ω/kft) / 1000(ft/kft))
The line to line voltage drop V in volts (V) is equal to square root of 3 times the wire current I in amps (A) times one way wire length L in meters (m) times the wire resistance per 1000 meters R in ohms (Ω/km) divided by 1000:
Vdrop (V) = √3 × Iwire (A) × Rwire (Ω)
= 1.732 × Iwire (A) × (L(m) × Rwire (Ω/km) / 1000(m/km))
Wire diameter calculations
The n gauge wire diameter dn in inches (in) is equal to 0.005in times 92 raised to the power of 36 minus gauge number n, divided by 39:
dn (in) = 0.005 in × 92(36-n)/39
The n gauge wire diameter dn in millimeters (mm) is equal to 0.127mm times 92 raised to the power of 36 minus gauge number n, divided by 39:
dn (mm) = 0.127 mm × 92(36-n)/39
Wire cross-sectional area calculations
The n gauge wire’s cross-sectional area An in kilo-circular mils (kcmil) is equal to 1000 times the square wire diameter d in inches (in):
An (kcmil) = 1000×dn2 = 0.025 in2 × 92(36-n)/19.5
The n gauge wire’s cross-sectional area An in square inches (in2) is equal to pi divided by 4 times the square wire diameter d in inches (in):
An (in2) = (π/4)×dn2 = 0.000019635 in2 × 92(36-n)/19.5
The n gauge wire’s cross-sectional area An in square millimeters (mm2) is equal to pi divided by 4 times the square wire diameter d in millimeters (mm):
An (mm2) = (π/4)×dn2 = 0.012668 mm2 × 92(36-n)/19.5
Wire resistance calculations
The n gauge wire resistance R in ohms per kilofeet (Ω/kft) is equal to 0.3048×1000000000 times the wire’s resistivity ρ in ohm-meters (Ω·m) divided by 25.42 times the cross-sectional area An in square inches (in2):
Rn (Ω/kft) = 0.3048 × 109 × ρ(Ω·m) / (25.42 × An (in2))
The n gauge wire resistance R in ohms per kilometer (Ω/km) is equal to 1000000000 times the wire’s resistivity ρ in ohm-meters (Ω·m) divided by the cross-sectional area An in square millimeters (mm2):
Rn (Ω/km) = 109 × ρ(Ω·m) / An (mm2)
You can find more information on calculating Voltage Drop at EC&M Magazine.
Industry Links for 2000 MCM / 2000 KCMIL Cable.
- Aluminum Association
- ASTM
- IEEE Power & Energy Society
- IEEE Industry Applications Society
- Underwriters Laboratories (UL)
- Insulated Cable Engineers Association (ICEA)
- International Council on Large Electric Systems (CIGRE)
- International Electrotechnical Commission (IEC)
- National Electric Safety Code (NESC)
- Towers, Poles & Conductors (TP&C)
Additional Large Sized MCM / KCMIL Cables from 1X Technologies:
- 250 MCM.
- 300 MCM.
- 350 MCM.
- 400 MCM.
- 500 MCM.
- 600 MCM.
- 750 MCM.
- 800 MCM.
- 900 MCM.
- 1000 MCM.
- 1250 MCM
- 1500 MCM.
- 1750 MCM.
- 2000 MCM.
- 2500 MCM.
- 2750 MCM.
- 3000 MCM.
- 3500 MCM.
- 4000 MCM.
- 4500 MCM.
- 5000 MCM.
- 5500 MCM.
- 6000 MCM.