DLO Cable – Specs, amps, applications, sizes, pricing, wire cost

DLO Cable, DLO Cost, DLO Specification, DLO Price, Buy DLO

1X Technologies DLO Cable Manufacturers – Diesel Locomotive Cable 

What is a DLO cable?

DLO Cable stands for “Diesel locomotive cables” or DLO Wire. DLO Cable was originally developed for wiring diesel-electric locomotive trains dating back before the 1920s, over 100 years ago. Back then, these heavy-duty 1kV and 2KV Diesel Locomotive cables were used as power leads in traction motors. The DLO Cables were used as open wiring to the Diesel Electric motors where they were made to take a massive amount of wear and tear. In today’s world,  DLO cables (Also called Type DEL Cable or Type DEL Wire) are still used in wiring diesel-electric locomotives, but more commonly used in applications such as Submersible Pump cable, battery cable, Belden DLO Cable, control panel power distribution, VFD power feed and as motor leads, earth moving equipment, drilling rigs, marine shipboard cable, in open air or in conduit wherever durability and wear and tear are prevalent. DLO cables are (UL) listed as RHH/RHW-2 2kV and available in sizes 14 AWG through 1111 Kcmil, temperature rated 90 degrees C. When DLO Cable is used as conductors for general wiring practices according to NEC Article 310 based on their RHW/RHW-2 listing the conductor’s cable class is subject to the requirements of NFPA 70 / NEC Article 310 the same as any other RHW insulated conductors. When used in general wiring as RHW-RHW-2 it is direct burial rated. There is no better source for purchasing your cable, give us a chance to earn your business. Contact us today at 1-888-651-9990 to get updated pricing on your DLO Cable. We’ll quickly get you a DLO cable cost to price your job.  

 

 

Request My DLO Cable Price Quote

Get your quick, hassle-free price quotation on DLO Cable, right now. Please fill out the secure form below and be sure to include your quantity required, wire & cable description, and delivery location in your message, and your 1X Technologies representative will respond quickly. If you still have questions, call us at 1-888-651-9990. We are available to answer questions Monday through Friday, 9 am – 6 pm MST.

 

 

 

1X Technologies Diesel Locomotive Cable Construction:

  • Nominal voltage: RHH/RHW-2 600V and 2000V, RW-90 CSA, 1kV, DLO 2kV
  • Conductors: Flexible strand tin coated copper conductor, B-172, ASTM B-33
  • Separator: Tape separator between conductor and insulation
  • DLO Wire Insulation: Ethylene-propylene rubber (EPR), UL, CSA, ICEA, AAR RP-588, 90ºC
  • DLO Jacket: Black heavy-duty, thermoset CPE, ICEA S-95-658 NEMA WC70, AAR RP-586  (Also available in Colors)

 

DLO Cable Applications

  • wiring diesel-electric locomotives for over 100 years 
  • General Building Wire (UL 44) RHH/RHW-2
  • Deep Well Submersible Pump cable
  • Petrochemical drilling rigs – Offshore and Onshore –   MSHA
  • Battery Cable
  • Arc Welding Cable
  • control panel power distribution
  • VFD power feed and as motor leads
  • Telecom Power Supply   (Central Office Power Cable)
  • earth moving equipment
  • drilling rigs
  • marine shipboard cable
  • In open air or in conduit wherever durability and wear and tear are prevalent
  • Jobs flexible heavy duty power cables
  • portable or fixed installations
  • Leads for motors, generators, batteries, jumper cables
  • For use in renewable energy applications such as Solar Photovoltaic, Wind Power, and more.
  • 2kv rhh rhw-2 applications

 

 

DLO cable chart,  Cut sheet, Data Sheet  – Specification

  1. DLO Cable part numbers
  2. DLO Cable Sizes
  3. DLO Cable Stranding
  4. DLO Cable Insulation and Jacket Thickness (EPDM)
  5. DLO Cable Diameter  – O.D.
  6. DLO Weight per 1000 Feet
  7. DLO Cable Amps / Ampacity
1XT Part # DLO Sizes Strands Insul. (in) Jacket (in)  O.D. (in) LBS/MFT Amps
DLO-14 14 19/27 0.045 0.015 0.218 30  35
DLO-12 12 19/25 0.045 0.015 0.240 46 40
DLO-10 10 27/24 0.045 0.015 0.266 67 55
DLO-8 8 37/.0211 0.065 0.030 0.3363 105 80
DLO-6 6 61/24 0.065 0.030 0.3807 146 105
DLO-4 4 105/24 0.065 0.030 0.4503 205 140
DLO-2 2 161/24 0.065 0.045 0.5020 293 190
DLO-1 1 210/24 0.085 0.045 0.6500 392 220
DLO-1/0 1/0 266/24 0.085 0.045 0.6900 525 260
DLO-2/0 2/0 342/24 0.085 0.045 0.7300 660 300
DLO-3/0 3/0 418/24 0.085 0.045 0.8100 760 350
DLO-4/0 4/0 551/24 0.080 0.045 0.8700 930 405
DLO-262.6 262.6 646/24 0.100 0.065 0.9200 1130 467
DLO-313.1 313.1 779/24 0.100 0.065 0.9680 1400 518
DLO-373.7 373.7 931/24 0.100 0.065 1.0650 1545 588
DLO-444.4 444.4 1102/24 0.100 0.065 1.1320 1820 649
DLO-535.3 535.3 1330/24 0.125 0.065 1.2400 2023 725
DLO-646.4 646.4 1590/24 0.125 0.065 1.3590 2560 814
DLO-777.7 777.7 1924/24 0.125 0.065 1.3820 3050 900
DLO-929.2 929.2 2299/24 0.120 0.065 1.6700 3123 1014
DLO-1111 1111.0 2745/24 0.140 0.065 1.8400 4354 1115

 

 

DLO cable ampacity / DLO cable amps / DLO cable current rating

DLO Cable Ampacity varies from 35 Amps up to 1115 Amps depending on which size you require. Diesel Locomotive Cable “Ampacity” is defined as the maximum current, in amperes, that a DLO Cable conductor can carry continuously under the conditions of use without exceeding its 90C temperature rating. This is also described as dlo cable current rating, its current-carrying capacity. The ampacity of a DLO Wire conductor depends on its ability to dissipate heat without damage to the conductor or its EPDM Rubber insulation. DLO cable amps is a function of the insulation temperature rating, the electrical resistance of the conductor material, the ambient temperature, and the ability of the insulated conductor to dissipate heat.    

 

DLO Cable UL, NEC, CSA  (2kv rhh rhw-2)

1.1  UL 44 – This (UL) Standard specifies the requirements for single-conductor and multiple-conductor thermoset-insulated wires and cables rated 600 V, 1000 V, 2000 V, and 5000 V, for use in accordance with the rules of the Canadian Electrical Code, Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, in Mexico, and the National Electrical Code (NEC), NFPA 70, in the United States of America. See Annex a for the complete list of types and voltage ratings covered by this Standard and the specific electrical codes for which they are intended, and Annex b for a summary of construction and test requirements for these types. 1.2 Table 1 provides a summary of the maximum conductor temperature, voltage ratings, and the number of insulated conductors for the types to which this Standard applies. 1.3 This Standard also specifies the requirements for submersible pump cables, with or without jackets, in Deep Well Submersible Water-Pump Cable, Section 7. No type-letter designations are assigned to these cables. 1.4 Products within this Standard might have applications not covered by the electrical codes listed in 1.1.

  • UL:  (CPE jacket) RHW-2 90C wet and dry, VW-1, Sun Res, for 1/0 and larger ST-1, FT-4, IEEE1202, for CT use
  • C(UL):  TYPE RW90 EP; 1000V; FT1
  • CSA:  RW-90 90C; FT1; FT4; -40C; for 1/0AWG and larger: OIL RES, Tray Cable, Sun Res

 

Can DLO cable be used in conduit?

When used as General Wiring in accordance with the NEC, DLO Cable (DLO Wire) can be used in Conduit. DLO Cable or DLO Wire is listed as UL 44 RHH-RHW-2 which is a building wire. When DLO Cable is used as conductors for general wiring practices according to NEC Article 310 based on their RHW/RHW-2 listing the conductors cable class is subject to the requirements of NFPA 70 / NEC Article 310 the same as any other RHW insulated conductors, and therefore just as any other RHW insulated conductors such as XLP— USE building wire, may be used in conduit. DLO cable conduit fill may be calculated using any of the accessible calculators commonly found online.  

 

DLO Cable Bending Radius

During electrical installation, DLO cables and DLO Wires are bent or flexed in various environmental conditions. Diesel Locomotive Cables are often bent around a curve in conduits or underground ducts. Cables are also bent when pulling a DLO electrical cable around a sheave, which is a pulley set up in a manhole to help ease a cable around a curve. Type DEL Cables (DLO) is composed of different components that may become compromised if bent too far and stress is placed on the electrical cable. To prevent cable damage, cable standards such as The National Electrical Code (NEC) and the Insulated Cable Engineers Association (ICEA) formed requirements for minimum bend radius. DLO Cable Bending radius: For fixed installation – minimum 4 x O.D., for flexible or temporary installation – minimum 6 x O.D. Diameter of the cable.    

 

DLO Cable Cost  – Price Per Foot

Diesel Locomotive Cable costs more than your typical general building wire due to its construction being composed of extremely durable components. Being a super flexible stranded tinned copper 2KV cable with an extra durable EPDM insulation and CPE jacket makes for a really amazing cable, but it can be pricey if you are comparing to standard THHN or XHHW. Pricing can range from $.25 cents per foot for 14 AWG to upwards of $40.00 per foot for 1111 MCM DLO Cable. Pricing depends on how many feet are ordered, where it is shipping, what copper base is at time of order and a variety of other factors. To get your current DLO cable cost give us a call today at 1-888-651-9990.  

 

1XTech DLO Cable Sizes  / DLO Wire Sizes

14 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 14 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 14 AWG DLO Cable Ampacity — Amperage: 35 Amps
  • Weight per 1000 Feet: 30 lbs.
  • Direct Burial Rated?   Yes
  • 14 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .218 In.
  • Bend Radius Fixed (x4): .872 In.
  • Bend Radius Flexible (x6):  1.308 In.
  • Low Smoke?   Yes
  • MSHA:  Yes
  • UL / CSA: Yes
  • 14 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 14 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

12 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 12 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 12 AWG DLO Cable Ampacity — Amperage: 40 Amps
  • Weight per 1000 Feet: 46 lbs.
  • Direct Burial Rated?   Yes
  • 12 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .240 In.
  • Bend Radius Fixed (x4): .960 In.
  • Bend Radius Flexible (x6):  1.44 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 12 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 12 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

10 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 10 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 10 AWG DLO Cable Ampacity — Amperage: 55 Amps
  • Weight per 1000 Feet: 67 lbs.
  • Direct Burial Rated?   Yes
  • 10 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .266 In.
  • Bend Radius Fixed (x4): 1.064 In.
  • Bend Radius Flexible (x6):  1.596 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 10 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 10 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

8 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 8 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 8 AWG DLO Cable Ampacity — Amperage: 80 Amps
  • Weight per 1000 Feet: 105 lbs.
  • Direct Burial Rated?   Yes
  • 8 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .3363 In.
  • Bend Radius Fixed (x4): 1.3452 In.
  • Bend Radius Flexible (x6):  2.0178 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 8 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 8 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

6 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 6 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 6 AWG DLO Cable Ampacity — Amperage: 105 Amps
  • Weight per 1000 Feet: 146 lbs.
  • Direct Burial Rated?   Yes
  • 6 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .3807 In.
  • Bend Radius Fixed (x4): 1.5228 In.
  • Bend Radius Flexible (x6):  2.2842 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 6 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 6 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

4 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 4 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 4 AWG DLO Cable Ampacity — Amperage: 140 Amps
  • Weight per 1000 Feet: 205 lbs.
  • Direct Burial Rated?   Yes
  • 4 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .4503 In.
  • Bend Radius Fixed (x4): 1.8012 In.
  • Bend Radius Flexible (x6):  2.7018 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 4 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 4 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

2 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 2 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 2 AWG DLO Cable Ampacity — Amperage: 190 Amps
  • Weight per 1000 Feet: 293 lbs.
  • Direct Burial Rated?   Yes
  • 2 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .502 In.
  • Bend Radius Fixed (x4): 2.008 In.
  • Bend Radius Flexible (x6):  3.012 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 2 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 2 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

1 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 1 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 1 AWG DLO Cable Ampacity — Amperage: 220 Amps
  • Weight per 1000 Feet: 392 lbs.
  • Direct Burial Rated?   Yes
  • 1 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .650 In.
  • Bend Radius Fixed (x4): 2.600 In.
  • Bend Radius Flexible (x6):  3.900 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 1 AWG DLO CT Use for Cable Trays?   No – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 1 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

1/0 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 1/0 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 1/0 AWG DLO Cable Ampacity — Amperage: 260 Amps
  • Weight per 1000 Feet: 525 lbs.
  • Direct Burial Rated?   Yes
  • 1/0 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .6900 In.
  • Bend Radius Fixed (x4): 2.760 In.
  • Bend Radius Flexible (x6):  4.140 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 1/0 AWG DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 1/0 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

2/0 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 2/0 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 2/0 AWG DLO Cable Ampacity — Amperage: 300 Amps
  • Weight per 1000 Feet: 660 lbs.
  • Direct Burial Rated?   Yes
  • 2/0 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .7300 In.
  • Bend Radius Fixed (x4): 2.920 In.
  • Bend Radius Flexible (x6):  4.380 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 2/0 AWG DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 2/0 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

3/0 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 3/0 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 3/0 AWG DLO Cable Ampacity — Amperage: 350 Amps
  • Weight per 1000 Feet: 760 lbs.
  • Direct Burial Rated?   Yes
  • 3/0 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .810 In.
  • Bend Radius Fixed (x4): 3.240 In.
  • Bend Radius Flexible (x6):  4.860 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 3/0 AWG DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 3/0 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

4/0 AWG Diesel Locomotive Cable 2KV

  • DLO Size: 4/0 AWG DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 4/0 AWG DLO Cable Ampacity — Amperage: 405 Amps
  • Weight per 1000 Feet: 930 lbs.
  • Direct Burial Rated?   Yes
  • 4/0 AWG DLO Cable Dimensions, Outside Diameter  O.D. — .870 In.
  • Bend Radius Fixed (x4): 3.480 In.
  • Bend Radius Flexible (x6):  5.220 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 4/0 AWG DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 4/0 AWG DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

262 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 262 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 262 MCM DLO Cable Ampacity — Amperage: 467 Amps
  • Weight per 1000 Feet: 1130 lbs.
  • Direct Burial Rated?   Yes
  • 262 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — .920 In.
  • Bend Radius Fixed (x4): 3.680 In.
  • Bend Radius Flexible (x6):  5.520 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 262 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 262 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

313 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 313 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 313 MCM DLO Cable Ampacity — Amperage: 518 Amps
  • Weight per 1000 Feet: 1400 lbs.
  • Direct Burial Rated?   Yes
  • 313 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — .9680 In.
  • Bend Radius Fixed (x4): 3.872 In.
  • Bend Radius Flexible (x6):  5.808 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 313 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 313 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

373 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 373 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 373 MCM DLO Cable Ampacity — Amperage: 588 Amps
  • Weight per 1000 Feet: 1545 lbs.
  • Direct Burial Rated?   Yes
  • 373 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.0650 In.
  • Bend Radius Fixed (x4): 4.260 In.
  • Bend Radius Flexible (x6):  6.390 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 373 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 373 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

444 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 444 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 444 MCM DLO Cable Ampacity — Amperage: 649 Amps
  • Weight per 1000 Feet: 1820 lbs.
  • Direct Burial Rated?   Yes
  • 444 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.1320 In.
  • Bend Radius Fixed (x4): 4.528 In.
  • Bend Radius Flexible (x6):  6.792 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 444 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 444 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

535 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 535 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 535 MCM DLO Cable Ampacity — Amperage: 725 Amps
  • Weight per 1000 Feet: 2023 lbs.
  • Direct Burial Rated?   Yes
  • 535 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.240 In.
  • Bend Radius Fixed (x4): 4.960 In.
  • Bend Radius Flexible (x6):  7.440 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 535 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 535 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

646 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 646 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 646 MCM DLO Cable Ampacity — Amperage: 814 Amps
  • Weight per 1000 Feet: 2560 lbs.
  • Direct Burial Rated?   Yes
  • 646 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.359 In.
  • Bend Radius Fixed (x4): 5.436 In.
  • Bend Radius Flexible (x6):  8.154 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 646 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 646 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

777 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 777 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 777 MCM DLO Cable Ampacity — Amperage: 900 Amps
  • Weight per 1000 Feet: 3050 lbs.
  • Direct Burial Rated?   Yes
  • 777 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.382 In.
  • Bend Radius Fixed (x4): 5.528In.
  • Bend Radius Flexible (x6):  8.292 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 777 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 777 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

929 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 929 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 929 MCM DLO Cable Ampacity —  Amperage: 1014 Amps
  • Weight per 1000 Feet: 3123 lbs.
  • Direct Burial Rated?   Yes
  • 929 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.670 In.
  • Bend Radius Fixed (x4): 6.680 In.
  • Bend Radius Flexible (x6):  10.020 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 929 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 929 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

1111 MCM Diesel Locomotive Cable 2KV

  • DLO Size: 1111 MCM DLO Cable
  • Voltage: RHH/RHW-2 600V & 2000V, RW-90 CSA, 1kV, DLO 2kV
  • 1111 MCM DLO Cable Ampacity — Amperage: 1115 Amps
  • Weight per 1000 Feet: 4354 lbs.
  • Direct Burial Rated?   Yes
  • 1111 KCMIL DLO Cable Dimensions, Outside Diameter  O.D. — 1.840 In.
  • Bend Radius Fixed (x4): 7.360 In.
  • Bend Radius Flexible (x6): 11.040 In.
  • Low Smoke?   Yes
  • MSHA?  Yes
  • UL / CSA: Yes
  • 1111 MCM DLO CT Use for Cable Trays?   Yes – DLO TC Cable on sizes 1/0 and larger. See NEC Article 310 General Wiring (RHH-RHW-2)
  • Can 1111 MCM DLO cable be used in conduit?  Yes – See NEC Article 310 General Wiring (RHH-RHW-2)

 

 

 

Diesel Locomotive Cable available in colors

1X Technologies Color Code for DLO

1X Technologies supplies DLO Cable in more colors than just standard black. Additionally we can apply thick factory applied tracer stripes which cover 40% of the conductor jacket with the color of your choice. Whatever color DLO you require we are ready to help you get the job done right.

  DLO Cable Color DLO Tracer Color
1 Black   (standard)
2 White
3 Green
4 Red
5 Orange
6 Blue
7 White Black
8 Red Black
9 Green Black
10 Orange Black
11 Blue Black
12 Black White
13 Red White
14 Green White
15 Blue White
16 Black Red
17 White Red
18 Orange Red
19 Blue Red
20 Red Green
21 Orange Green

*Note: DLO Cable Colors repeat after 21 conductors.    

Manufacturing Extra Large sizes:

1X Technologies manufactures and supplies extra large DLO type Cable Sizes offering you larger and bigger cables when you need higher amperage for your application. You may purchase DLO Cable up to 4000 KCMIL / 4000 MCM with very low minimum order quantities.

 

 

Aluminum DLO Cable

If you require an aluminum DLO Cable and are purchasing a bulk quantity for your wind turbine tower or solar photo-voltaic array we can offer you our Copper Clad Aluminum conductors offering you a product much lighter than copper and a bit heavier than just bare aluminum. The density of Copper Clad Aluminum is about 35% lighter than copper. This product meets or exceeds the minimum requirements set forth in ASTM B 566 04. The Aluminum DLO would be used as Aluminum (UL 44) RHH-RHW-2 per NEC Article 310 for General Wiring Practices.  

Short Run Capability

Do you just need a short run of cable for your project? We specialize in manufacturing prototypes and short runs to help our customers when they need to finish a project or if they need to replace a damaged cable.  

Rapid Manufacturing

Are you in an emergency situation where you need your cable delivered right away? Rapid manufacturing is our specialty. Call 1-888-651-9990 now.    

DLO cable lugs & Connectors

1X Technologies provides DLO Cable Lugs and Connectors for each size we sell. If you require a special connector or lug type we can manufacture that for you or source something specific from many of our supply chain partners such as Burndy, Panduit, 3M, Belden, and more!  Contact us today to order your DLO Cable lugs and connectors.