1XTECH 1/C CU 2000V EPR RHH/RHW-2 LSZH AC / DC TRACTION POWER CABLE COMPANY
Contact us today for your price estimate on 1XTech® Traction Power Cable 2000 Volt Single Conductor Copper, Super Clean Ethylene Propylene Rubber (EPR) insulation RHH/RHW-2 EnviroTech® Low Smoke Zero Halogen (LSZH) Jacket. We produce the BIG sizes of DC Traction Power Cable such as 1000 MCM, 1250 MCM, 1500 MCM, 1750 MCM, 2000 MCM, 2250 MCM, 2500 MCM, 2750 MCM, 3000 MCM up to 6000 KCMIL. The standard Traction Power cable or Traction Power Wire is 600V and 2kV, but we can produce as 5kV, 15kV, 25kV, 35kV up to 550kV depending on your project scope. Our Traction Power Cable has been specified by Traction Power Engineers from coast to coast, New York to Los Angeles and always stands the test of time.
What is Traction Power Cable? Traction Power Wire is a heavy-duty industrial cable used in traction substations, traction current converter plants and traction power substations (TPSS). Traction Power is an electrical substation that converts electric power from the form provided by the electrical power industry for public utility service to an appropriate voltage, current type and frequency to supply railways, trams (streetcars) or trolleybuses with traction current.
Traction Power Wire Manufacturing Construction:
- AC / DC Traction Power Conductor: Class B or C compressed stranded copper. Center strand embossed with “1XTechnologies, Year, Plant” when required.
- Binder Tape: Mylar Tape (Manufactured with premium Mylar)
- Insulation: Clean Ethylene Propylene Rubber (EPR) Type RHH/RHW-2
- Overall Jacket: EnviroTech® Low Smoke Zero Halogen (LSZH) Jacket
AC / DC TRACTION CABLE APPLICATIONS AND FEATURES:
1XTechnologies 2000V EPR/EnviroTech Traction-Power-Cable is suited for use in mass transit and general industrial applications where flexibility, fire resistance, and low smoke generation are a concern. Our AC / DC Traction Power Cable may be installed in wet or dry locations in cable trays or raceways. These cables are capable of operating continuously at a conductor temperature, not in excess of 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Resistance to moisture and most oils, acids, and alkalis with an overall durable LSZH XLPO jacket. Meets Flame Spread and Smoke Release requirements of NFPA 130. Alternate constructions available upon request.
Traction Power Cable Specifications (PDF SPEC, CONTACT US):
- ASTM B3 Soft or annealed copper
- ASTM B8 Concentric-lay-standard copper
- ASTM B33 Tin coated copper conductors
- UL 44 Thermoset Insulated wires and cables
- UL 1685 – Flame Test
- IEEE 1202/FT4 – Flame Test (70,000 Btu/hr Vertical Tray Test)
- ICEA S-95-658 NEMA WC70 – Power Cables rated 2000 volts or less for the distribution of electrical energy
- NFPA 130 – Standard for Fixed Guideway Transit and Passenger Rail Systems SAMPLE PRINT LEGEND: 1XTECH EXXXXX #P# (UL) [#AWG Or #kcmil] CU RHH/RHW-2 EPR/LSZH 2000V Type TC For CT USE SUN. RES. For DIRECT BURIAL FT4 [-25°C] YEAR (NESC) [SEQUENTIAL FEET MARKS]
250 MCM / 250 KCMIL AC / DC Traction Power Cable
1XTech 250 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 250 MCM /250 KCMIL / 37 Strand
- Diameter over conductor (In.): 0.558″
- Insulation Thickness (Mils): 75 Mils
- Diameter over insulation (In.): 0.708″
- Jacket Thickness (Mils): 65 Mils
- Approximate Outside Diameter O.D. (Inches): 0.838″
- Copper Weight (lbs/MFT): 772 lbs. per 1000 Feet
- Approximate Total Weight: 941 lbs. per 1000 Feet
1XTech 250 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 250 MCM / 250 KCMIL / 37 Strand
- Minimum Bending Radius (In.): 6.8 Inches
- Maximum Pulling Tension (lbs.): 2000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.043
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.054
- Reactance XL @ 60Hz Ω/MFT: 0.031
- Ø Short Circuit Current 6 Cycles Amps: 56854
- Allowable Ampacities – 60 Degrees C Amps: 215
- Allowable Ampacities – 75 Degrees C Amps: 255
- Allowable Ampacities – 90 Degrees C Amps: 290
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
350 MCM / 350 KCMIL AC / DC Traction Power Cable
1XTech 350 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 350 MCM / 350 KCMIL / 37 Strand
- Diameter over conductor (In.): 0.661″
- Insulation Thickness (Mils): 75 Mils
- Diameter over insulation (In.): 0.811″
- Jacket Thickness (Mils): 65 Mils
- Approximate Outside Diameter O.D. (Inches): 0.941″
- Copper Weight (lbs/MFT): 1081 lbs. per 1000 Feet
- Approximate Total Weight: 1291 lbs. per 1000 Feet
1XTech 350 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 350 MCM / 350 KCMIL / 37 Strand
- Minimum Bending Radius (In.): 7.5 Inches
- Maximum Pulling Tension (lbs.): 2800 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.031
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.039
- Reactance XL @ 60Hz Ω/MFT: 0.030
- Ø Short Circuit Current 6 Cycles Amps: 79583
- Allowable Ampacities – 60 Degrees C Amps: 260
- Allowable Ampacities – 75 Degrees C Amps: 310
- Allowable Ampacities – 90 Degrees C Amps: 350
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
500 MCM / 500 KCMIL AC / DC Traction Power Cable
1XTech 500 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 500 MCM / 500 KCMIL / 37 Strand
- Diameter over conductor (In.): 0.789″
- Insulation Thickness (Mils): 75 Mils
- Diameter over insulation (In.): 0.939″
- Jacket Thickness (Mils): 65 Mils
- Approximate Outside Diameter O.D. (Inches): 1.069″
- Copper Weight (lbs/MFT): 1544 lbs. per 1000 Feet
- Approximate Total Weight: 1788 lbs. per 1000 Feet
1XTech 500 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 500 MCM / 500 KCMIL / 37 Strand
- Minimum Bending Radius (In.): 8.6 Inches
- Maximum Pulling Tension (lbs.): 4000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.022
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.028
- Reactance XL @ 60Hz Ω/MFT: 0.029
- Ø Short Circuit Current 6 Cycles Amps: 113690
- Allowable Ampacities – 60 Degrees C Amps: 319
- Allowable Ampacities – 75 Degrees C Amps: 381
- Allowable Ampacities – 90 Degrees C Amps: 430
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
750 MCM / 750 KCMIL AC / DC Traction Power Cable
1XTech 750 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 750 MCM / 750 KCMIL / 61 Strand
- Diameter over conductor (In.): 0.968
- Insulation Thickness (Mils): 90 Mils
- Diameter over insulation (In.): 1.148
- Jacket Thickness (Mils): 65 Mils
- Approximate Outside Diameter O.D. (Inches): 1.278
- Copper Weight (lbs/MFT): 2316 lbs. per 1000 Feet
- Approximate Total Weight: 2632 lbs. per 1000 Feet
1XTech 750 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 750 MCM / 750 KCMIL / 61 Strand
- Minimum Bending Radius (In.): 10.2 Inches
- Maximum Pulling Tension (lbs.): 6000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.014
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.020
- Reactance XL @ 60Hz Ω/MFT: 0.028
- Ø Short Circuit Current 6 Cycles Amps: 170535
- Allowable Ampacities – 60 Degrees C Amps: 397
- Allowable Ampacities – 75 Degrees C Amps: 474
- Allowable Ampacities – 90 Degrees C Amps: 535
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
1000 MCM / 1000 KCMIL AC / DC Traction Power Cable
1XTech 1000 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 1000 MCM / 1000 KCMIL / 127 Strand
- Diameter over conductor (In.): 1.117
- Insulation Thickness (Mils): 90 Mils
- Diameter over insulation (In.): 1.431
- Jacket Thickness (Mils): 65 Mils
- Approximate Outside Diameter O.D. (Inches): 1.427
- Copper Weight (lbs/MFT): 3088 lbs. per 1000 Feet
- Approximate Total Weight: 3445 lbs. per 1000 Feet
1XTech 1000 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 1000 MCM / 1000 KCMIL / 127 Strand
- Minimum Bending Radius (In.): 11.4 Inches
- Maximum Pulling Tension (lbs.): 8000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.011
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.016
- Reactance XL @ 60Hz Ω/MFT: 0.027
- Ø Short Circuit Current 6 Cycles Amps: 227380
- Allowable Ampacities – 60 Degrees C Amps: 456
- Allowable Ampacities – 75 Degrees C Amps: 545
- Allowable Ampacities – 90 Degrees C Amps: 615
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
1500 MCM / 1500 KCMIL AC / DC Traction Power Cable
1XTech 1500 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 1500 MCM / 1500 KCMIL / 91 Strand
- Diameter over conductor (In.): 1.370
- Insulation Thickness (Mils): 115 Mils
- Diameter over insulation (In.): 1.600
- Jacket Thickness (Mils): 95 Mils
- Approximate Outside Diameter O.D. (Inches): 1.790
- Copper Weight (lbs/MFT): 4631 lbs. per 1000 Feet
- Approximate Total Weight: 5251 lbs. per 1000 Feet
1XTech 1500 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 1500 MCM / 1500 KCMIL / 91 Strand
- Minimum Bending Radius (In.): 14.32 Inches
- Maximum Pulling Tension (lbs.): 12000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.007
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.012
- Reactance XL @ 60Hz Ω/MFT: 0.028
- Ø Short Circuit Current 6 Cycles Amps: 341069
- Allowable Ampacities – 60 Degrees C Amps: 525
- Allowable Ampacities – 75 Degrees C Amps: 625
- Allowable Ampacities – 90 Degrees C Amps: 705
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
2000 MCM / 2000 KCMIL AC / DC Traction Power Cable
1XTech 2000 MCM AC / DC Traction Power Cable Mechanical Specifications
- Conductor Size AWG / Strands: 2000 MCM / 2000 KCMIL / 127 Strand
- Diameter over conductor (In.): 1.583
- Insulation Thickness (Mils): 115 Mils
- Diameter over insulation (In.): 1.813
- Jacket Thickness (Mils): 95 Mils
- Approximate Outside Diameter O.D. (Inches): 2.003
- Copper Weight (lbs/MFT): 6175 lbs. per 1000 Feet
- Approximate Total Weight: 6842 lbs. per 1000 Feet
1XTech 2000 MCM AC / DC Traction Power Cable Electrical Specifications
- Conductor Size AWG / Strands: 2000 MCM / 2000 KCMIL / 127 Strand
- Minimum Bending Radius (In.): 16.0 Inches
- Maximum Pulling Tension (lbs.): 16000 lbs.
- DC Resistance – DC @ 25 Degrees Celsius Ω/MFT: 0.005
- AC Resistance – DC @ 90 Degrees Celsius Ω/MFT: 0.010
- Reactance XL @ 60Hz Ω/MFT: 0.027
- Ø Short Circuit Current 6 Cycles Amps: 454759
- Allowable Ampacities – 60 Degrees C Amps: 556
- Allowable Ampacities – 75 Degrees C Amps: 665
- Allowable Ampacities – 90 Degrees C Amps: 750
(Ampacities are based on Table 310.15 (B)(16) of the NEC, 2014 Edition. Ampacities of insulated conductors rated up to and including 2000 Volts, based on the ambient temperature of 30ºC (86ºF))
Traction Power Cable Resistance and Voltage Drop Calculator via YouTube Video (14 Minutes 16 Seconds)
This is a very good video from Dunwoody College teaching resistance and voltage drop you may use for your Traction Power Cable calculations.
Contact us today to order your 1X Technologies Traction Power Cable.
Call 1-888-651-9990.
Thank you!
Because You Require Quality Quickly! ®